Flat grinder


Release time:

2024-01-31

Reduction gearbox 1. When using a new gearbox, the new oil needs to be replaced after 300 hours of operation, and the lubricating oil needs to be replaced every 1500 hours of use. The quality of the oil should still be checked regularly during use. If there is less oil, it should be added in a timely manner. If the oil deteriorates or ages, it must be replaced immediately. 2. The gearbox should use a fixed brand and number of lubricating oil, and it is not allowed to mix different brands, numbers, or types of lubricating oil together. 3. During the oil change process, the oil inside the gearbox should be cleaned first (blown clean with an air gun), and then new oil should be injected. 4. During use, if the oil temperature exceeds 80 ℃, the machine should be stopped for inspection. After the temperature drops, the lubricating oil should be replaced before normal use. 5. Recommended oil: ISO HD-460 or medium oil HD-320 lubricating oil. 6. The oil level of the engine oil must be checked every 2 days, and for gearboxes with less oil, it is necessary to add oil in a timely manner (the depth of the oil should be in the center of the oil mirror). 7. The oil injection hole of the gearbox must not be blocked and must have an air release function. 8. The working environment of the gearbox must be ventilated. 9. The maximum speed of the gearbox generally cannot exceed revolutions per minute.

Flat grinder

Reduction gearbox
1. When using a new gearbox, the new oil needs to be replaced after 300 hours of operation, and the lubricating oil needs to be replaced every 1500 hours of use. The quality of the oil should still be checked regularly during use. If there is less oil, it should be added in a timely manner. If the oil deteriorates or ages, it must be replaced immediately.
2. The gearbox should use a fixed brand and number of lubricating oil, and it is not allowed to mix different brands, numbers, or types of lubricating oil together.
3. During the oil change process, the oil inside the gearbox should be cleaned first (blown clean with an air gun), and then new oil should be injected.
4. During use, if the oil temperature exceeds 80 ℃, the machine should be stopped for inspection. After the temperature drops, the lubricating oil should be replaced before normal use.
5. Recommended oil: ISO HD-460 or medium oil HD-320 lubricating oil.
6. The oil level of the engine oil must be checked every 2 days, and for gearboxes with less oil, it is necessary to add oil in a timely manner (the depth of the oil should be in the center of the oil mirror).
7. The oil injection hole of the gearbox must not be blocked and must have an air release function.
8. The working environment of the gearbox must be ventilated.
9. The maximum speed of the gearbox generally cannot exceed revolutions per minute.
electrical machinery
1. The operating voltage of the motor is 380V, ensuring that it is used at normal voltage.
2. The maximum frequency for using the motor is 50Hz and cannot exceed 50Hz.
3. The maximum current intensity of the motor should not exceed 15A. If any abnormalities are found, it should be stopped and checked in a timely manner.
4. After the motor start switch is started, if it is found that the motor does not start immediately, it should be stopped immediately for inspection. Only after troubleshooting can it be used normally.
5. If any noise or high temperature (above 80 ℃) is found in the motor, it should be stopped immediately for inspection. Only after troubleshooting can it be used normally.